ExperimentID |
EXA000083 |
ChemicalID |
CH0001603
|
Chemical Name |
Octachloroheptadecane |
Official Method |
No |
Chromatography |
LC |
Chromatography mfr. |
1200SL, Agilent |
Column |
Inertsil C4 250 mm x 4.0 mm, 5 μm |
Column mfr. |
GL Sciences |
Detector |
MS/MS |
Detector mfr. |
6460, Agilent |
Ionization |
SRM-ESI-negative |
Extraction |
Soxhlet Extraction |
Extraction Details |
Extracted with Toluene |
Clean-up 1st |
Solvent Extraction |
Clean-up 1st Details |
Extracted with Hexane saturated acetonitrile, and then with Hexane |
Clean-up 2nd |
Column cleanup |
Clean-up 2nd Details |
44% Silica gel sulfate; Florisil (Magnesium silicate); Eluted with Dichloromethane/Hexane (20:80) |
Clean-up Spike |
|
Syringe Spike |
|
Derivatization |
|
Recovery Correction |
|
Instrument Detection Limit |
|
Instrument Quantification Limit |
|
Method Detection Limit |
0.83 ng/g dry |
Method Quantification Limit |
|
Repeatability |
|
Standard |
|
Recovery (CRM) |
|
Recovery (spiked) |
|
Recovery (IS) |
|
Protocol |
|
Remarks |
|
RegisterDate |
2021/3/16 |
UpdateDate |
2021/3/16 |