| ExperimentID | EXA000281 |
|---|---|
| ChemicalID | CH0001178 |
| Chemical Name | ΣChlorinated undecanes |
| Official Method | No |
| Chromatography | LC |
| Chromatography mfr. | ACQUITY UPLC I class, Waters |
| Column | ACQUITY UPLC BEH C18 50 mm x 2.1 mm, 1.7 μm |
| Column mfr. | Waters |
| Detector | MS |
| Detector mfr. | Xevo TQ-S, Waters |
| Ionization | SIR-APCI-negative |
| Extraction | Soxhlet Extraction |
| Extraction Details | Air collection: QFF, PUF and ACF; Extracted with Acetone and Toluene (QFF, ACF), with Acetone (PUF) |
| Clean-up 1st | Multilayer silica gel column cleanup |
| Clean-up 1st Details | Sulfuric acid/Silica gel (44:56), Sulfuric acid/Silica gel (22:78); Eluted with Dichloromethane/Hexane (15:85) |
| Clean-up 2nd | Column cleanup |
| Clean-up 2nd Details | Column cleanup:Florisil; Remove interfering substance with Hexane; Eluted with Dichloromethane/Hexane (15:85) |
| Clean-up Spike | |
| Syringe Spike | d18-β-HBCD |
| Derivatization | |
| Recovery Correction | |
| Instrument Detection Limit | |
| Instrument Quantification Limit | |
| Method Detection Limit | 40 pg/m3 |
| Method Quantification Limit | 110 pg/m3 |
| Repeatability | |
| Standard | |
| Recovery (CRM) | |
| Recovery (spiked) | |
| Recovery (IS) | |
| Protocol | https://www.env.go.jp/chemi/kurohon/2019/shosai/3_7.pdf |
| Remarks | Analysis method: p.455 |
| RegisterDate | 2021/6/04 |
| UpdateDate | 2021/6/04 |