Analytical methods

ExperimentID EXA000302
ChemicalID CH0001623
Chemical Name Cerium
Official Method No
Chromatography
Chromatography mfr.
Column
Column mfr.
Detector ICP-MS
Detector mfr. 7900, Agilent
Ionization
Extraction SPE
Extraction Details pH adjustment: pH 4-5; SPE extraction with InertSep ME-1 250mg/6mL, 10mL/min.
Clean-up 1st Washing
Clean-up 1st Details Cartridge: Washed with 0.4mol/L Ammonium acetate aqueous solution 5mL and puriied water 10mL
Clean-up 2nd Filtration
Clean-up 2nd Details Filtered with Fiter paper No. 5B, Advantec
Clean-up Spike
Syringe Spike Indium
Derivatization
Recovery Correction
Instrument Detection Limit
Instrument Quantification Limit
Method Detection Limit 0.15 ng/L
Method Quantification Limit
Repeatability
Standard
Recovery (CRM)
Recovery (spiked)
Recovery (IS)
Protocol https://www.env.go.jp/chemi/kurohon/2020/shosai/5_1_2.pdf
Remarks Analysis method: p.5
RegisterDate 2022/1/25
UpdateDate 2022/1/25