| ExperimentID | EXA000321 |
|---|---|
| ChemicalID | CH0001055 |
| Chemical Name | Pyridine |
| Official Method | No |
| Chromatography | GC |
| Chromatography mfr. | 6890 GC, Agilent |
| Column | TG-WAXMS B 60m x 0.25mm, 0.25μm; (Two 30m-columns connected with a column connector) |
| Column mfr. | TraceGOLD |
| Detector | MS |
| Detector mfr. | JMS-K9, JEOL |
| Ionization | SIM-EI |
| Extraction | SPE |
| Extraction Details | InertSep RP-1 mini (Three columns connected in series), 0.3L/min. x 24h; Eluted with Acetone |
| Clean-up 1st | |
| Clean-up 1st Details | |
| Clean-up 2nd | |
| Clean-up 2nd Details | |
| Clean-up Spike | |
| Syringe Spike | Pyridine-d5 |
| Derivatization | |
| Recovery Correction | |
| Instrument Detection Limit | |
| Instrument Quantification Limit | |
| Method Detection Limit | 2.4 ng/m3 |
| Method Quantification Limit | |
| Repeatability | |
| Standard | |
| Recovery (CRM) | |
| Recovery (spiked) | |
| Recovery (IS) | |
| Protocol | https://www.env.go.jp/chemi/kurohon/2020/shosai/5_1_2.pdf |
| Remarks | Analysis method: p.9 |
| RegisterDate | 2022/2/22 |
| UpdateDate | 2022/2/22 |