Analytical methods

ExperimentID EXA000441
ChemicalID CH0000500
Chemical Name Pentachlorobenzene
Official Method No
Chromatography GC
Chromatography mfr. 6890, Agilent; 7683, Agilent
Column RH-12ms 60 m x 0.25 mm
Column mfr. INVENTX
Detector HRMS
Detector mfr. AutoSpec Ultima, Waters; AutoSpec Premier, Waters
Ionization SIM-EI
Extraction Solvent Extraction
Extraction Details Extracted with Acetone.
Clean-up 1st Malti-layer column cleanup
Clean-up 1st Details Malti-layer column cleanup: Florisil, Anhydrous sodium sulfate; Eluted with Hexane (First fraction), Dichloromethane/Hexane (50:50) (Second fraction)
Clean-up 2nd Malti-layer column cleanup
Clean-up 2nd Details Malti-layer column cleanup: Silica Gel, Copper powder, Silica Gel Sulfate, Anhydrous sodium sulfate. Eluted with Hexane
Clean-up Spike 13C12-Pentachlorobenzene
Syringe Spike 13C12-PCB#9, #19, #70, #111, #155, #178 or #202
Derivatization
Recovery Correction
Instrument Detection Limit
Instrument Quantification Limit
Method Detection Limit 0.4 pg/g dry
Method Quantification Limit 0.9 pg/g dry
Repeatability
Standard
Recovery (CRM)
Recovery (spiked)
Recovery (IS)
Protocol https://www.env.go.jp/chemi/kurohon/2020/shosai/5_3_2.pdf
Remarks Analysis method: p4; Resolution: 10,000
RegisterDate 2022/7/12
UpdateDate 2022/7/12