ExperimentID |
EXA000455 |
ChemicalID |
CH0001180
|
Chemical Name |
ΣChlorinated tridecanes |
Official Method |
No |
Chromatography |
GC |
Chromatography mfr. |
7200 Q-TOF, Agilent |
Column |
DB-5ms 60 m x 0.25 mm |
Column mfr. |
Agilent |
Detector |
TOF-MS |
Detector mfr. |
7200 Q-TOF, Agilent |
Ionization |
EI or NICI |
Extraction |
Solvent Extraction |
Extraction Details |
Ultrasonic extraction: Extracted with Acetone. After filtration, the residue: Soxhlet Extraction: Extracted with Toluene. |
Clean-up 1st |
Sulfate treatment |
Clean-up 1st Details |
Sulfate |
Clean-up 2nd |
Malti-layer column cleanup; Column cleanup |
Clean-up 2nd Details |
Malti-layer column cleanup: Silica Gel, Copper powder, Silica Gel Sulfate, Anhydrous sodium sulfate. Eluted with Hexane (First fraction), Dichloromethane/Hexane (20:80) (Second fraction); Column cleanup: Potassium hydroxide/Silica Gel (2:98), Eluted with Dichloromethane/Hexane (50:50) |
Clean-up Spike |
|
Syringe Spike |
13C12-PCB#9, #19, #70, #111, #115, #178, #202 or #209 |
Derivatization |
|
Recovery Correction |
|
Instrument Detection Limit |
|
Instrument Quantification Limit |
|
Method Detection Limit |
1000 pg/g dry |
Method Quantification Limit |
2000 pg/g dry |
Repeatability |
|
Standard |
|
Recovery (CRM) |
|
Recovery (spiked) |
|
Recovery (IS) |
|
Protocol |
https://www.env.go.jp/chemi/kurohon/2020/shosai/5_3_2.pdf |
Remarks |
Analysis method: p20; Resolution: 13,000 |
RegisterDate |
2022/7/12 |
UpdateDate |
2022/7/12 |