ExperimentID |
EXA000564 |
ChemicalID |
CH0000831
|
Chemical Name |
Σnona-BDEs |
Official Method |
No |
Chromatography |
GC |
Chromatography mfr. |
HP6890GC, Agilent |
Column |
BP1 15 m x 0.25 mm, 0.10 μm |
Column mfr. |
SGE |
Detector |
HRMS |
Detector mfr. |
AutoSpec Premier, Waters |
Ionization |
SIM-EI |
Extraction |
Soxhlet Extraction |
Extraction Details |
Air collection: QFF, PUF and ACF; Extracted with Acetone and Toluene (QFF, ACF), with Acetone (PUF) |
Clean-up 1st |
Column cleanup |
Clean-up 1st Details |
Column cleanup: Supelclean Sulfoxide 6 g; Remove interfering substance with Hexane; Eluted with Acetone |
Clean-up 2nd |
Multilayer column cleanup |
Clean-up 2nd Details |
Silica gel, Sulfuric acid/Silica gel (22:78), Sulfuric acid/Silica gel (44:56), Silica gel, Potassium hydroxide/Slica gel (2:98), Silica gel; Eluted with Hexane (First fraction), Dichloromethane/Hexane (50:50)(Second fraction) |
Clean-up Spike |
13C12-PBDE#47, #99, #153, #154, #183, #204, #207, #209 |
Syringe Spike |
13C12-PBDE#138 |
Derivatization |
|
Recovery Correction |
|
Instrument Detection Limit |
|
Instrument Quantification Limit |
|
Method Detection Limit |
0.1 pg/m3 |
Method Quantification Limit |
0.3 pg/m3 |
Repeatability |
|
Standard |
|
Recovery (CRM) |
|
Recovery (spiked) |
|
Recovery (IS) |
|
Protocol |
https://www.env.go.jp/chemi/kurohon/2020/shosai/5_3_2.pdf |
Remarks |
Analysis method: p.6; Resolution: 10,000 |
RegisterDate |
2022/9/27 |
UpdateDate |
2022/9/27 |