ExperimentID |
EXA000608 |
ChemicalID |
CH0000613
|
Chemical Name |
Octamethylcyclotetrasiloxane |
Official Method |
No |
Chromatography |
GC |
Chromatography mfr. |
7890B, Agilent |
Column |
J&W DB-5ms 30 m x 0.25 mm, 0.25 μm (connected with non-polar precolumn 1 m x 0.32 mm) |
Column mfr. |
Agilent |
Detector |
MS |
Detector mfr. |
7000C, Agilent |
Ionization |
SIM-EI |
Extraction |
SPE |
Extraction Details |
Heat the water sample in the gas-washing bottle up to 50 ℃ and insonate it while aeration for 120 min.; Sep-Pac Plus PS-2; Eluted with Hexane |
Clean-up 1st |
|
Clean-up 1st Details |
|
Clean-up 2nd |
|
Clean-up 2nd Details |
|
Clean-up Spike |
Octamethylcyclotetrasiloxane-13C8 |
Syringe Spike |
naphthalene-d8 |
Derivatization |
|
Recovery Correction |
|
Instrument Detection Limit |
|
Instrument Quantification Limit |
|
Method Detection Limit |
2.7 ng/L |
Method Quantification Limit |
|
Repeatability |
|
Standard |
|
Recovery (CRM) |
|
Recovery (spiked) |
|
Recovery (IS) |
|
Protocol |
https://www.env.go.jp/chemi/kurohon/2021/shosai/5_2_2.pdf |
Remarks |
Analysis method: p.3 |
RegisterDate |
2022/11/25 |
UpdateDate |
2022/11/25 |