| ExperimentID | EXA000626 |
|---|---|
| ChemicalID | CH0001665 |
| Chemical Name | [(3-Tetradecanamidopropyl)(dimethyl)ammonio]acetate |
| Official Method | No |
| Chromatography | LC |
| Chromatography mfr. | 1260, Agilent |
| Column | Inertsil ODS-4 HP 150 mm x 2.1 mm, 3 μm |
| Column mfr. | GL Sciences |
| Detector | MS/MS |
| Detector mfr. | QTRAP 4500QT, AB Sciex |
| Ionization | SRM-ESI-positive |
| Extraction | Solvent Extraction |
| Extraction Details | Extracted with 28 % Ammonia water / Methanol (5:95) 30 mL, Shaken and kept still standing at 70 ℃ for 15 min. Then, centrifuged 3,000 rpm for 10 min. ( 20 min. in the 3rd round); Repeated these procedures three times |
| Clean-up 1st | Column cleanup |
| Clean-up 1st Details | Sep-Pak PS2 Plus Short Cartridge, 225 mg / 80 μm; Run the extract through the cartridge at 2 mL / min.; Remove interfering substance with purified water 2 mL, formic acid / purified water (2:98) 5 mL, Methanol 10 mL; Eluted with 28 % Ammonia water / Methanol (5:95) 10 mL. |
| Clean-up 2nd | Column cleanup |
| Clean-up 2nd Details | Oasis MCX Plus Short Cartridge 225 mg / 60 μm; Run the extract (through the former column cleanup) through the cartridge at 2 mL / min.; Remove interfering substance with purified water 5 mL; Eluted with Methanol 10 mL. |
| Clean-up Spike | |
| Syringe Spike | |
| Derivatization | |
| Recovery Correction | |
| Instrument Detection Limit | |
| Instrument Quantification Limit | |
| Method Detection Limit | 0.94 ng/g dry |
| Method Quantification Limit | |
| Repeatability | |
| Standard | |
| Recovery (CRM) | |
| Recovery (spiked) | |
| Recovery (IS) | |
| Protocol | https://www.env.go.jp/chemi/kurohon/2021/shosai/5_2_2.pdf |
| Remarks | Analysis method: p.2 |
| RegisterDate | 2022/12/08 |
| UpdateDate | 2022/12/08 |