| ExperimentID | EXA000758 |
|---|---|
| ChemicalID | CH0001520 |
| Chemical Name | Dicofol |
| Official Method | No |
| Chromatography | GC |
| Chromatography mfr. | 7890, Agilent |
| Column | DB-5ms 15 m x 0.25 mm |
| Column mfr. | Agilent |
| Detector | MS/MS |
| Detector mfr. | 7010, Agilent |
| Ionization | MRM-EI |
| Extraction | Solvent Extraction |
| Extraction Details | Extracted with Dichloromethane |
| Clean-up 1st | Column cleanup |
| Clean-up 1st Details | Florisil, Anhydrous sodium sulfate; Remove interfering substance with Hexane; Eluted with Dichloromethane/Hexane (50:50) |
| Clean-up 2nd | |
| Clean-up 2nd Details | |
| Clean-up Spike | Dicofol-13C12 |
| Syringe Spike | Naphthalene-d8; Acenaphtene-d10; Phenanthrene-d10; Fluoranthene-d10; Chrysene-d12; Decane |
| Derivatization | |
| Recovery Correction | |
| Instrument Detection Limit | |
| Instrument Quantification Limit | |
| Method Detection Limit | 5 pg/L |
| Method Quantification Limit | 13 pg/L |
| Repeatability | |
| Standard | |
| Recovery (CRM) | |
| Recovery (spiked) | |
| Recovery (IS) | |
| Protocol | https://www.env.go.jp/chemi/kurohon/2021/shosai/5_3_2.pdf |
| Remarks | Analysis method: p.13 |
| RegisterDate | 2023/1/26 |
| UpdateDate | 2023/1/26 |