ProjectID | SampleID | Sample | Chemical | ExperimentID | MeasuredValue | Unit | Remarks | RegisterDate |
---|---|---|---|---|---|---|---|---|
PRA000099 | SAA006757 | Air | Σhexa-CBs | 4.00E+0 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | PCB126 | tr(1.20E-2) | pg/m3 | 9.00E-3 (LOD) < This value < 2.30E-2 (LOQ) | 2020/1/15 | |
PRA000099 | SAA006757 | Air | PCB123 | tr(1.80E-2) | pg/m3 | 8.00E-3 (LOD) < This value < 2.00E-2 (LOQ) | 2020/1/15 | |
PRA000099 | SAA006757 | Air | PCB118 | 8.80E-1 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | PCB114 | 2.60E-2 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | PCB105 | 2.50E-1 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | Σpenta-CBs | 1.30E+1 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | PCB81 | tr(1.00E-2) | pg/m3 | 1.00E-2 (LOD) < This value < 3.00E-2 (LOQ) | 2020/1/15 | |
PRA000099 | SAA006757 | Air | PCB77 | 5.50E-2 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | Σtetra-CBs | 9.50E+0 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | Σtri-CBs | 1.00E+1 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | Σdi-CBs | 1.20E+1 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | Σmono-CBs | 5.10E+0 | pg/m3 | 2020/1/15 | ||
PRA000099 | SAA006757 | Air | ΣPCBs | 5.40E+1 | pg/m3 | 2020/1/15 |